Clinical efficacy of high-flow nasal cannula compared to noninvasive ventilation in patients with post-extubation respiratory failure

Article information

Korean J Intern Med. 2016;31(1):82-88
Publication date (electronic) : 2015 December 28
doi : https://doi.org/10.3904/kjim.2016.31.1.82
Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
Correspondence to Chae-Man Lim, M.D. Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea Tel: +82-2-3010-3135 Fax: +82-2-3010-6968 E-mail: cmlim@amc.seoul.kr
*

These authors contributed equally to this work.

Current affiliation: Department of Internal Medicine, Gyeongsang National University Hospital, Jinju, Korea

Received 2014 September 2; Revised 2014 October 21; Accepted 2014 October 21.

Abstract

Background/Aims:

Post-extubation respiratory failure (PERF) is associated with poor clinica l outcomes. High-f low nasa l cannula (HF NC) ox ygen therapy has been used in patients with respiratory failure, but the clinical benefit in patients with PERF remains unclear. The aim of this study was to evaluate the clinical efficacy of HFNC compared to noninvasive ventilation (NIV) in patients with PERF.

Methods:

A historic retrospective cohort analysis was performed in 28 beds in the medical Intensive Care Unit (ICU) at a single medical center in South Korea. In total, 73 patients with PERF were enrolled: 39 patients who underwent NIV from April 2007 to March 2009 and 34 patients who received HFNC from April 2009 to May 2011.

Results:

The rate of avoidance of reintubation was not different between the HFNC group (79.4%) and NIV group (66.7%, p = 0.22). All patients with HFNC tolerated the device, whereas five of those with NIV did not tolerate treatment (p = 0.057). The mean duration of ICU stay was significantly shorter in the HFNC group than in the NIV group (13.4 days vs. 20.6 days, p = 0.015). There was no difference in ICU or in-hospital mortality rate.

Conclusions:

HFNC is likely to be as effective as, and better tolerated than, NIV for treatment of PERF.

INTRODUCTION

Post-extubation respiratory failure (PERF) occurs in ~10% to 20% of patients with planned extubation and results in reintubation [1-3]. Reintubation due to PERF is associated with poor outcomes, including an increased incidence of ventilator-associated pneumonia, increased mortality rates, and longer Intensive Care Unit (ICU) and hospital stays [4-6]. An international consensus conference considered noninvasive ventilation (NIV) to be a promising modality in terms of avoiding reintubation associated with PERF and improving clinical outcomes [7]. However, two randomized clinical trials did not demonstrate a benefit of NIV in terms of avoiding reintubation in patients with PERF [8,9].

A high-flow nasal cannula (HFNC), a relatively new oxygenation device, provides adequate heated humidity in addition to a high flow of oxygen. Due to the high flow rate of gas, HFNC can produce a continuous positive airway pressure effect in the airway, and thus may exert a favorable physiologic effect [10]. Due to the combination of these effects, HFNC may serve to improve oxygenation, maintain bronchial hygiene, and alleviate respiratory distress [11]. Several studies have reported the usefulness of HFNC in patients with acute respiratory failure, showing beneficial effects on clinical signs and oxygenation [12-15]. Although one work investigated the clinical outcomes in pediatric, and especially neonatal, populations [16], studies focusing on the clinical outcomes of HFNC—such as reintubation, mortality, or ICU stay—in adults with PERF. are lacking. The aim of our study was to evaluate the clinical outcomes of HFNC in patients with PERF compared to those of NIV.

METHODS

Patients

This historic retrospective study was conducted in a university-affiliated hospital with a 28-bed medical ICU in Seoul, South Korea. Medical record charts were reviewed retrospectively. Two groups were established based on the period of treatment: the first group (NIV group) included patients who received treatment from April 2007 to March 2009, while the second group (HFNC group) included patients who underwent treatment from April 2009 to May 2011. The Institutional Review Board of Asan Medical Center approved this study. The requirement for informed consent was waived due to the retrospective nature of the analysis.

Inclusion and exclusion criteria

Medical patients ≥ 18 years old who had been extubated were enrolled. Respiratory failure that developed within 48 hours was regarded as PERF, and NIV or HFNC was performed. Respiratory failure was defined as clinical signs of increased effort on breathing (such as active contraction of the accessory respiratory muscles) that developed within 48 hours of extubation, plus one of the following: (1) respiratory acidosis (defined as an arterial pH < 7.35 with a partial pressure of arterial carbon dioxide of > 45 mmHg); (2) respiratory rate greater than 25 breaths per minute; (3) hypoxemia defined as (partial pressure of oxygen [PaO2]/fraction of inspired oxygen [FiO2] < 300 mmHg or pulse oxygen saturation [SpO2] of < 90%). Patients were excluded if they had ‘do-not-resuscitate’ status or a previous experience of home bilevel positive airway pressure (BiPAP).

NIV protocol: before undergoing NIV, patients were positioned with their beds at a 45° angle. The patient put on an orofacial mask to function as an interface. In the pressure support mode with > 4 cmH2O positive end-expiratory pressure, an initial target estimated tidal volume of 6 mL per predicted kilogram of body weight and a respiratory rate of less than 24 breaths per minute were set. The FiO2 was titrated to maintain the SpO2 at > 90%.

HFNC (Optiflow; Fisher & Paykel Healthcare, Auckland, New Zealand) protocol: oxygen was supplied via HFNC, using an initial inspiratory flow rate of 30 L/min and was titrated until the respiratory effort of patients was minimized. FiO2 was adjusted to achieve a SpO2 of > 90%.

Data collection

Avoidance of reintubation, duration of ICU and hospital stay, ICU and hospital mortality rates, and incidence of ICU-acquired pneumonia associated with PERF were evaluated and compared between the two groups. Device intolerance was defined as patients’ refusal of continuous use of devices. The avoidance of reintubation was defined as no reintubation due to respiratory failure after applying HFNC or NIV during the ICU stay.

ICU-acquired pneumonia was defined using either clinical criteria (new or progressive radiologic pulmonary infiltrate together with at least two of the following: temperature > 38°C or < 36°C, leukocytosis > 12,000/mm3 or leukopenia < 4,000/mm3, or purulent respiratory secretions) or a simplified Clinical Pulmonary Infectious Score greater than or equal to six points [17].

Statistical analysis

Categorical and non-categorical variables are expressed as number (percentage) and mean ± standard deviation, respectively. The Fisher exact or chi-square test was used to compare categorical variables. The Mann-Whitney U test was used for comparisons of non-categorical variables. A value of p ≤ 0.05 was considered to indicate statistical significance. The SPSS version 18.0 (SPSS Inc., Chicago, IL, USA) was used for data analysis.

RESULTS

Baseline characteristics of the enrolled patients

A total of 73 patients were enrolled in this study: in the first-period group, 39 patients underwent NIV for the treatment of PERF, while in the second-period group, 34 subjects were treated by HFNC. Of all patients, 43 patients (58.9%) were males. Their age was 62.6 ± 16.3 years. The baseline characteristics of the enrolled patients are shown in Table 1. There was no significant difference in gender, age, or Acute Physiology and Chronic Health Evaluation II or Sequential Organ Failure Assessment score between the two groups. The proportion of neoplasm as an underlying disease was higher in the NIV group than the HFNC group. Acute heart failure was a more common cause of acute respiratory failure in the NIV group than in the HFNC group. Duration of invasive mechanical ventilation until extubation did not differ between the two groups. There was a trend toward shorter duration from extubation to the onset of respiratory failure in the HFNC group.

Baseline characteristics of the enrolled patients

Physiologic parameters and laboratory data of patients with PERF

The physiologic parameters and laboratory findings of patients at the onset of PERF are summarized in Table 2. Regarding vital signs, only body temperature differed significantly between the two groups. In the arterial blood gas analysis results, lower pH, higher partial pressure of carbon dioxide, and lower arterial blood saturation were found in the NIV group compared to the HFNC group. There was a trend toward lower levels of sodium and potassium in the HFNC group. Other laboratory data did not differ between the two groups.

Physiologic parameters and laboratory findings of the patients at the onset of post-extubation respiratory failure

Comparison of clinical outcomes between the NIV and HFNC groups

The clinical outcomes of the NIV and HFNC groups are described in Table 3. Overall, 53 patients (72.6%) did not require reintubation during their ICU stay. The rate of avoidance of reintubation was not significantly different between the two groups (66.7% for NIV vs. 79.4% for HFNC, p = 0.223). Device intolerance occurred in five patients (12.8%) with NIV, whereas there was no device intolerance in patients with HFNC (p = 0.057). Four of the five patients that did not tolerate NIV progressed to respiratory failure and were reintubated. In the HFNC group, seven patients progressed to severe respiratory failure, all of whom were reintubated and received invasive mechanical ventilation. A total of 20 patients (27.4%) were reintubated (33.3% in the NIV group vs. 20.6% in the HFNC group, p = 0.531). The rates of reintubation and application of invasive mechanical ventilation were not significantly different between the two groups. The reasons for reintubation were similar in the two groups: refractory hypoxemia was the most common cause (6/39, 46.2% for NIV vs. 4/34, 57.1% for HFNC, p = 0.531). There was no difference in the rate of tracheostomy between the two groups (6/13, 46.2% in the NIV group vs. 4/7, 57.1% in the HFNC group, p = 1.0). The duration of ICU stay from extubation was significantly shorter in the HFNC group than in the NIV group (6.8 ± 9.6 days vs. 10.4 ± 11.1 days, p = 0.013), but the duration of ICU stay from the onset of PERF to general ward in ICU survivors did not differ significantly between the groups (7.8 ± 9.2 days in the NIV group vs. 4.6 ± 5.6 days in the HFNC group, p = 0.856). The length of hospital stay was similar between the two groups (52.9 ± 38.7 days in the NIV group vs. 48.7 ± 40.5 days in the HFNC group, p = 0.367). There was no significant difference in the rate of ICU-acquired pneumonia after extubation (20.5% in the NIV group vs. 17.6% in the HFNC group, p = 0.756), ICU (20.5% in the NIV group vs. 8.8% in the HFNC group, p = 0.164), or in-hospital mortality (41% in the NIV group vs. 23.5% in the HFNC group, p = 0.112) between the two groups.

Comparison of clinical outcomes between the NIV and HFNC groups.

Subgroup analysis of outcome variables according to the presence of hypercapnia

Further outcomes analyses according to the presence of hypercapnia were performed since the baseline level of PaCO2 differed significantly between the NIV and HFNC groups (Table 4). In the 50 patients with PaCO2 < 45 mmHg, patients with HFNC showed a lower ICU mortality rate (3.6% vs. 27.3%, p = 0.034) and in-hospital mortality rate (14.3% vs. 40.9%, p = 0.033), as well as a trend toward a lower incidence of reintubation than those with NIV (85.7% vs. 63.6%, p = 0.07). In the 23 patients with a PaCO2 > 45 mmHg, there were no significant differences in the above outcome variables between the two groups.

Analysis of outcome variables according to arterial carbon dioxide pressure.

DISCUSSION

In patients with PERF, our study showed that HFNC exhibited a similar efficacy to NIV in terms of avoidance of reintubation in patients with PERF. In addition, HFNC was better tolerated, and associated with a shorter ICU stay, compared to NIV. In patients without hypercapnia (as indicated by a PaCO2 < 45 mmHg at the onset of PERF), HFNC was associated with lower ICU and in-hospital mortality rates than NIV.

Extubation is a critical step in patients who receive invasive mechanical ventilation. Despite recent advances in mechanical ventilation, PERF develops in ~10% to 20% of patients who meet weaning criteria [1,2]. Reintubation due to PERF is associated with poor outcomes and a mortality rate of up to 50% [3,5,6]. Therefore, an effective intervention is required to prevent or reverse PERF to avoid reintubation. Previously, NIV was considered a promising therapy and recommended in patients with PERF [7]. However, two randomized studies failed to show beneficial effects of NIV in patients who develop respiratory failure after extubation. Indeed, the mortality rate was higher in the NIV group in two studies [8,9]. The benefit of NIV as a treatment for PERF was evident only in patients with hypercapnic respiratory failure [18,19].

Heated and humidified HFNC was recently introduced to ICUs. It supplies up to 100% heated and humidified oxygen at a maximum flow rate of 60 L/min via a nasal prong or cannula. By delivering a continuous high flow of oxygen, the pharyngeal dead space is washed out, nasopharyngeal resistance is reduced and some positive end expiratory pressure is generated, all of which contribute to a reduction in the work of breathing [10,11]. The heated humidification facilitates secretion clearance and expectoration of bronchial secretions. It also increases patient comfort because high-flow oxygen is delivered via a nasal cannula, and does not interrupt eating, drinking or talking. In addition, HFNC therapy has not been associated with pneumonia or barotrauma. A few reports have demonstrated the clinical benefits of HFNC, as shown by alleviation of symptoms and improvement of respiratory parameters such as respiratory rate, arterial blood oxygen partial pressure or saturation in patients with acute respiratory failure [12-15]. Two studies have reported that HFNC is equal or more effective than a simple mask in extubated patients in terms of tolerance and delivering oxygen [20,21]. However, the clinical efficacy of HFNC in PERF patients has not been reported to date. The present study indicates that HFNC is not inferior to NIV. Especially in patients with PERF without hypercapnia (i.e., PERF with dominant hypoxia), clinical outcomes such as duration of ICU stay and in-hospital mortality rate were more favorable with HFNC than with NIV. The clinical outcomes of PERF patients with hypercapnia did not differ significantly between HFNC and NIV.

There were several limitations to this study. First, because of its retrospective design and the small number of enrolled patients, the possibility of selection bias cannot be excluded. Second, as a single-center cohort was analyzed, the results cannot be generalized. Third, the group of patients with hypercapnic PERF was small, and so the results of comparison of HFNC and NIV in such cases should be verified.

In conclusion, HFNC may be at least equivalent to NIV in patients with PERF in terms of avoiding reintubation. HFNC oxygen therapy is associated with shorter ICU stay in patients with PERF. In subjects without hypercapnic PERF, ICU and in-hospital survival rates were improved by HFNC.

KEY MESSAGE

1. High-f low nasal cannula (HFNC) oxygen therapy was associated with shorter Intensive Care Unit stay in patients with post-extubational respiratory failure compared with noninvasive ventilation (NIV).

2. HFNC may not be inferior to NIV in terms of avoiding the need for reintubation.

Notes

No potential conflict of interest relevant to this article was reported.

References

1. Epstein SK, Ciubotaru RL, Wong JB. Effect of failed extubation on the outcome of mechanical ventilation. Chest 1997;112:186–192.
2. Esteban A, Alia I, Gordo F, et al. Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation: the Spanish Lung Failure Collaborative Group. Am J Respir Crit Care Med 1997;156(2 Pt 1):459–465.
3. Epstein SK, Ciubotaru RL. Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med 1998;158:489–493.
4. Torres A, Gatell JM, Aznar E, et al. Re-intubation increases the risk of nosocomial pneumonia in patients needing mechanical ventilation. Am J Respir Crit Care Med 1995;152:137–141.
5. Thille AW, Harrois A, Schortgen F, Brun-Buisson C, Brochard L. Outcomes of extubation failure in medical intensive care unit patients. Crit Care Med 2011;39:2612–2618.
6. Frutos-Vivar F, Esteban A, Apezteguia C, et al. Outcome of reintubated patients after scheduled extubation. J Crit Care 2011;26:502–509.
7. Organized jointly by the American Thoracic Society, ; the European Respiratory Society, ; the European Society of Intensive Care Medicine, ; the Societe de Reanimation de Langue Francaise, ; approved by ATS Board of Directors, ; December 2000. International Consensus Conferences in Intensive Care Medicine: noninvasive positive pressure ventilation in acute respiratory failure. Am J Respir Crit Care Med 2001;163:283–291.
8. Keenan SP, Powers C, McCormack DG, Block G. Noninvasive positive-pressure ventilation for postextubation respiratory distress: a randomized controlled trial. JAMA 2002;287:3238–3244.
9. Esteban A, Frutos-Vivar F, Ferguson ND, et al. Noninvasive positive-pressure ventilation for respiratory failure after extubation. N Engl J Med 2004;350:2452–2460.
10. Groves N, Tobin A. High flow nasal oxygen generates positive airway pressure in adult volunteers. Aust Crit Care 2007;20:126–131.
11. Ward JJ. High-flow oxygen administration by nasal cannula for adult and perinatal patients. Respir Care 2013;58:98–122.
12. Sztrymf B, Messika J, Bertrand F, et al. Beneficial effects of humidified high flow nasal oxygen in critical care patients: a prospective pilot study. Intensive Care Med 2011;37:1780–1786.
13. Sztrymf B, Messika J, Mayot T, Lenglet H, Dreyfuss D, Ricard JD, et al. Impact of high-flow nasal cannula oxygen therapy on intensive care unit patients with acute respiratory failure: a prospective observational study. J Crit Care 2012;27:324.e9–324.e13.
14. Roca O, Riera J, Torres F, Masclans JR. High-flow oxygen therapy in acute respiratory failure. Respir Care 2010;55:408–413.
15. Parke RL, McGuinness SP, Eccleston ML. A preliminary randomized controlled trial to assess effectiveness of nasal high-flow oxygen in intensive care patients. Respir Care 2011;56:265–270.
16. Manley BJ, Owen LS, Doyle LW, et al. High-flow nasal cannulae in very preterm infants after extubation. N Engl J Med 2013;369:1425–1433.
17. Esperatti M, Ferrer M, Theessen A, et al. Nosocomial pneumonia in the intensive care unit acquired by mechanically ventilated versus nonventilated patients. Am J Respir Crit Care Med 2010;182:1533–1539.
18. Nava S, Gregoretti C, Fanfulla F, et al. Noninvasive ventilation to prevent respiratory failure after extubation in high-risk patients. Crit Care Med 2005;33:2465–2470.
19. Ferrer M, Valencia M, Nicolas JM, Bernadich O, Badia JR, Torres A. Early noninvasive ventilation averts extubation failure in patients at risk: a randomized trial. Am J Respir Crit Care Med 2006;173:164–170.
20. Tiruvoipati R, Lewis D, Haji K, Botha J. High-flow nasal oxygen vs high-flow face mask: a randomized crossover trial in extubated patients. J Crit Care 2010;25:463–468.
21. Rittayamai N, Tscheikuna J, Rujiwit P. High-flow nasal cannula versus conventional oxygen therapy after endotracheal extubation: a randomized crossover physiologic study. Respir Care 2014;59:485–490.

Article information Continued

Table 1.

Baseline characteristics of the enrolled patients

Characteristic NIV group (n = 39) HFNC group (n = 34) p value
Male sex 25 (64.1) 18 (52.9) 0.334
Age, yr 62.9 ± 16.1 62.1 ± 16.8 0.969
Acute Physiology and Chronic Health Evaluation II score 19.2 ± 3.9 19.7 ± 4.1 0.480
Sequential Organ Failure Assessment score 6.3 ± 3.5 5.5 ± 2.5 0.461
Underlying disease
 Diabetes mellitus 4 (10.3) 5 (14.7) 0.725
 Neoplasm 11 (28.2) 18 (52.9) 0.031
 Chronic lung disease 14 (35.9) 11 (32.4) 0.750
 Chronic heart disease 9 (23.1) 5 (14.7) 0.365
 Chronic renal disease 8 (20.5) 2 (5.9) 0.093
 Liver cirrhosis 4 (10.3) 3 (8.8) 1
Causes of mechanical ventilation before extubation
 Pneumonia 22 (56.4) 18 (52.9) 0.766
 Sepsis 8 (20.5) 10 (29.4) 0.379
 AE of chronic obstructive pulmonary disease 7 (17.9) 4 (11.8) 0.461
 AE of idiopathic pulmonary fibrosis 1 (2.6) 4 (11.8) 0.177
 Acute respiratory distress syndrome 2 (5.1) 5 (14.7) 0.240
 Acute heart failure 9 (23.1) 2 (5.9) 0.041
Duration of invasive MV before extubation, hr 182.9 ± 148.8 132.7 ± 85.6 0.243
Time elapsed from extubation to respiratory failure, hr 10.7 ± 11.6 8.6 ± 11.8 0.097

Values are presented as number (%) or mean ± SD.

NIV, noninvasive ventilation; HFNC, high-flow nasal cannula; AE, acute exacerbation; MV, invasive mechanical ventilation.

Table 2.

Physiologic parameters and laboratory findings of the patients at the onset of post-extubation respiratory failure

Variable NIV group (n = 39) HFNC group (n = 34) p value
Physiologic parameter
Systolic blood pressure, mmHg 131.8 ± 21.2 136.3 ± 16.9 0.678
Diastolic blood pressure, mmHg 64.2 ± 14.8 71.4 ± 10.8 0.224
Heart rate, beats/min 101.9 ± 21.7 102.6 ± 18.4 0.799
Respiratory rate, beats/min 22.8 ± 5.2 20.9 ± 6.0 0.115
Body temperature, °C 36.8 ± 0.6 36.6 ± 0.6 0.035
Arterial blood gas analysis
 pH 7.40 ± 0.1 7.48 ± 0.07 0.003
 PaO2, mmHg 76.4 ± 24.2 82.9 ± 30.3 0.419
 PaCO2, mmHg 48.2 ± 17.8 38.2 ± 6.6 0.030
 PaO2/FiO2 ratio 190.6 ± 82.8 188.9 ± 73.8 0.757
 Pulse oxygen saturation, % 93.3 ± 4.3 95.2 ± 3.4 0.032
White cell count, × 103 cells/μL 12 ± 6.5 13.6 ± 7.1 0.291
Hemoglobin, g/dL 9.9 ± 1.9 10.5 ± 1.9 0.162
Platelet, × 103 cells/μL 176.3 ± 133.6 185.8 ± 110.1 0.425
Albumin, g/dL 2.5 ± 0.5 2.6 ± 0.4 0.456
Sodium, mmol/L 138.9 ± 5.5 136.7 ± 4.2 0.099
Potassium, mmol/L 3.9 ± 0.4 3.6 ± 0.6 0.082

Values are presented as mean ± SD.

NIV, noninvasive ventilation; HFNC, high-flow nasal cannula; PaO2, partial pressure of oxygen; PaCO2, partial pressure of carbon dioxide; FiO2, inspired fraction of oxygen.

Table 3.

Comparison of clinical outcomes between the NIV and HFNC groups.

Variable NIV group (n = 39) HFNC group (n = 34) p value
Avoidance of reintubation 26 (66.7) 27 (79.4) 0.223
Total reintubation rates 13 (33.3) 7 (20.6) 0.223
Reasons for reintubation 0.531
 Refractory hypoxemia 6 (46.2) 4 (57.1)
 Refractory hypercapnia 3 (23.1) 0
 Excess respiratory secretions 1 (7.7) 1 (14.3)
 Cardiopulmonary arrest 2 (15.4) 1 (14.3)
 Changes in mental status 0 1 (14.3)
 Lack of improvement in signs of muscle fatigue 1 (7.7) 0
Tracheostomy 6/13 (46.2) 4/7 (57.1) 1.000
ICU stay, day 20.6 ± 14.2 13.4 ± 10.3 0.015
Post-extubation ICU stay, day 10.4 ± 11.1 6.8 ± 9.6 0.013
ICU stay after PERF in ICU survivors, day 7.8 ± 9.2 4.6 ± 5.6 0.856
Hospital stay, day 52.9 ± 38.7 48.7 ± 40.5 0.367
ICU-acquired pneumonia after extubation 8 (20.5) 6 (17.6) 0.756
ICU mortality 8 (20.5) 3 (8.8) 0.164
Hospital mortality 16 (41) 8 (23.5) 0.112

Values are presented as mean ± SD or number (%).

NIV, noninvasive ventilation; HFNC, high-flow nasal cannula; ICU, Intensive Care Unit; PERF, post-extubation respiratory failure.

Table 4.

Analysis of outcome variables according to arterial carbon dioxide pressure.

Outcome PaCO2 < 45 mmHg
PaCO2 ≥ 45 mmHg
NIV group (n = 22) HFNC group (n = 28) p value NIV group (n = 17) HFNC group (n = 6) p value
Avoidance of reintubation 14 (63.6) 24 (85.7) 0.070 12 (70.6) 3 (50) 0.363
ICU mortality 6 (27.3) 1 (3.6) 0.034 2 (11.8) 2 (33.3) 0.270
In-hospital mortality 9 (40.9) 4 (14.3) 0.033 7 (41.2) 4 (66.7) 0.371

Values are presented as number (%).

PaCO2, partial pressure of carbon dioxide; NIV, noninvasive ventilation; HFNC, high-flow nasal cannula; ICU, Intensive Care Unit.