Detection of Clopidogrel Hyporesponsiveness Using a Point-of-Care Assay and the Impact of Additional Cilostazol Administration after Coronary Stent Implantation in Diabetic Patients

Article information

Korean J Intern Med. 2011;26(2):145-152
Publication date (electronic) : 2011 June 01
doi : https://doi.org/10.3904/kjim.2011.26.2.145
1Division of Cardiology, Department of Internal Medicine & Cardiovascular Research Institute, Busan Paik Hospital, Inje University College of Medicine, Busan, Korea.
2Division of Cardiology, Department of Internal Medicine & Cardiovascular Research Institute, Haeundae Paik Hospital, Inje University College of Medicine, Busan, Korea.
3Division of Cardiology, Department of Internal Medicine, Yeungnam University Medical Center, Daegu, Korea.
4Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, Korea.
Correspondence to Doo-Il Kim, M.D. Division of Cardiology, Department of Internal Medicine & Cardiovascular Research Institute, Haeundae Paik Hospital, Inje University College of Medicine, 1435 Jwa-dong, Haeundae-gu, Busan 612-030, Korea. Tel: 82-51-890-6270, Fax: 82-51-892-0273, JO1216@inje.ac.kr
Received 2010 May 05; Revised 2010 August 26; Accepted 2011 March 08.

Abstract

Background/Aims

Impaired responsiveness to clopidogrel is common in patients with type 2 diabetes mellitus (DM). The aim of this study was to evaluate the clinical application of a point-of-care assay to detect impaired responsiveness to clopidogrel after coronary stent implantation in patients with type 2 DM.

Methods

We measured P2Y12 reaction units (PRU) with the VerifyNow point-of-care assay in 544 consecutive patients undergoing dual or triple (i.e., dual plus cilostazol) anti-platelet therapy after coronary stent implantation. High platelet reactivity (HPR) was defined as a PRU value ≥ 240.

Results

The mean PRU values were 233.5 ± 83.2 and 190.3 ± 85.5 in patients undergoing dual or triple anti-platelet therapy, respectively (p < 0.001). Patients with DM manifested higher post treatment PRU values (238.3 ± 82.4 vs. 210.8 ± 86.8, p = 0.001) and a higher frequency of HPR (44.8% vs. 31.0%, p = 0.003) as compared to patients without DM. We also found that higher PRU values and a higher frequency of HPR were present in patients with DM who were undergoing both triple and dual anti-platelet therapy. However, the higher post-treatment PRU values observed in patients with DM decreased with triple anti-platelet therapy (219.4 ± 82.5 vs. 247.9 ± 81.1, p = 0.044).

Conclusions

A point-of-care assay can detect elevated platelet reactivity and impaired responsiveness to clopidogrel in patients with type 2 DM. The addition of cilostazol to dual anti-platelet therapy may decrease post-treatment PRU values in patients with type 2 DM.

INTRODUCTION

Patients with type 2 diabetes mellitus (DM) have a higher risk of cardiovascular events and death than those without DM [1-3]. In addition, type 2 DM is a risk factor for stent thrombosis after drug-eluting stent implantation [4]. Elevated platelet reactivity, among other mechanisms, contributes to the increased risk of atherothrombotic complications in patients with type 2 DM [5,6]. Elevated platelet reactivity is more frequent in patients with type 2 DM than in those without DM, even when treated with dual anti-platelet therapy, such as aspirin and clopidogrel [7,8]. Cilostazol, a phosphodiesterase III inhibitor, has additional inhibitory effects on adenosine diphosphate (ADP) P2Y12 receptor-induced platelet aggregation when used with dual anti-platelet therapy [9,10].

Platelet reactivity traditionally has been measured using light transmittance aggregometry; however, problems with the clinical application of this method limit its routine use. The VerifyNow P2Y12 point-of-care assay (Accumetrics, San Diego, CA, USA) enables more simple and rapid measurements of platelet reactivity. Recent studies have shown that elevated platelet reactivity after clopidogrel therapy, as measured by a point-of-care assay, was associated with a higher risk of adverse events after percutaneous coronary intervention (PCI) [11,12].

The aim of this study was to evaluate the clinical application of a point-of-care assay to detect impaired clopidogrel responsiveness in patients with type 2 DM undergoing dual or triple (dual plus cilostazol) anti-platelet therapy after a PCI with stent implantation. In addition, the effects of cilostazol on platelet reactivity in patients with type 2 DM were evaluated.

METHODS

Study population

This study was conducted on 544 consecutive patients who underwent coronary stent implantation. Patients were enrolled in three hospitals (Inje University Busan Paik Hospital, Yeungnam University Hospital, and Keimyung University Dongsan Hospital) under a PCI registry. Patients who had received a loading dose of 300 mg or 600 mg clopidogrel and 200 mg aspirin at least 12 hours prior to the PCI or were on maintenance doses of 75 mg clopidogrel and 100 mg aspirin per day for more than 5 days were included in the study. Patients considered as having DM were those taking oral hypoglycemic agents or those who needed of insulin for adequate glucose control at the time of the PCI. Clinical data, including the results of the point-of-care assays, were collected prospectively. Exclusion criteria were as follows: 1) an ST segment elevation myocardial infarction while undergoing primary PCI; 2) a platelet count < 100 × 103/µL; 3) a serum creatinine > 2 mg/dL, and 4) patients who received periprocedural glycoprotein IIb/IIIa inhibitors. The local institutional review committees approved this study and all patients provided informed consent.

Medications

Coronary lesions were treated using standard PCI techniques. All patients received a daily maintenance dose of 75 mg clopidogrel and 100 mg aspirin. In addition, cilostazol, 200 mg daily, was prescribed in some patients. The addition of cilostazol was left to the discretion of the operators. Stent type selection and the use of glycoprotein IIb/IIIa antagonists were also left to the discretion of the operators. All patients received heparin during the procedure to maintain an activated clotting time ≥ 250 seconds and were prescribed lifelong aspirin.

Point-of-care assay

Venous blood was taken from each patient at least 2 days after the PCI and blood was drawn into a Greiner Bio-One 3.2% citrate Vacuette tube® (Greiner Bio-One, Monroe, NC, USA) and run within 60 minutes. The VerifyNow P2Y12 assay is a turbidmetry-based optical detection device that measures platelet responsiveness to clopidogrel and other P2Y12 antagonists. This system contains fibrinogen-coated polystyrene beads and measures changes in light transmission and thus the rate of aggregation in whole blood. This device has two whole-blood assay channels. One channel contains 20 µmol/L of ADP as an agonist. This channel also contains prostaglandin E1 as a suppressor of intracellular free calcium, which reduces the nonspecific contribution of ADP binding to P2Y1 receptors. Another separate channel contains an iso-thrombin receptor activating protein as an agonist. All results are expressed as P2Y12 reaction units (PRU). High platelet reactivity (HPR), as assessed by the point-of-care assay, was defined as a PRU value ≥ 240 according to the results of recent studies [11,12].

Statistical analysis

Comparisons were performed using a Student's t test or Mann-Whitney test and a chi-square or Fisher's exact test. A Kolmogorov-Smirnov test was used to test for normality. A multivariate logistic regression analysis was performed to identify independent predictors of HPR. All statistical tests were two-tailed and a p value < 0.05 was considered statistically significant. All calculations were performed using SPSS version 13 (SPSS Inc., Chicago, IL, USA).

RESULTS

From July 2007 to March 2009, we enrolled 544 consecutive patients in the current analysis. This study population included 154 diabetic patients. The baseline characteristics of all subjects are listed in Table 1. The diabetic group included 18 patients (11.7%) who needed insulin for adequate blood glucose control. Patients with DM had a higher frequency of hypertension (p = 0.01) and a lower level of creatinine clearance (p = 0.01) as calculated using the methods of Cockcroft and Gault, compared to those without DM. Patients with DM also had a longer stent length per lesion (p = 0.01) and a greater stent number per patient (p = 0.02) compared to those without DM. However, there were no significant differences in other coronary risk factors or medications, such as lipid lowering agents and anti-platelet agents.

Table 1

Baseline characteristics

Post-treatment PRU values were normally distributed (one-sample Kolmogorov-Smirnov test, p = 0.23). The mean post-treatment PRU values were 233.5 ± 83.2 and 190.3 ± 85.5 in patients undergoing dual or triple anti-platelet therapy, respectively (p < 0.001). Patients with DM had a higher post-treatment PRU compared to those without DM (238. 3 ± 82.4 vs. 210.8 ± 86.8, p = 0.001) (Fig. 1). Patients with DM also had a higher frequency of HPR compared to those without DM (44.8% vs. 31.0%, p = 0.003) (Fig. 2). The percentage of patients included in the 4th quartile of post-treatment PRU values was higher in patients with DM as compared to those without DM (32.5% vs. 23.3%, p = 0.03). Table 2 shows that higher post-treatment PRU values were observed in patients with DM undergoing both triple and dual anti-platelet therapy. The magnitude of the difference in PRU values between patients with and without DM was larger in patients undergoing triple anti-platelet therapy compared to those undergoing dual anti-platelet therapy. In patients with DM, the post-treatment PRU value was significantly lower in patients undergoing triple anti-platelet therapy as compared to those undergoing dual anti-platelet therapy (219.4 ± 82.5 vs. 247.9 ± 81.1, p = 0.044). Table 3 shows that patients with DM had a higher frequency of HPR regardless of the type of anti-platelet therapy. The frequency of HPR in patients with DM tended to be lower in patients undergoing triple anti-platelet therapy as compared to those undergoing dual anti-platelet therapy (34.6% vs. 50.0%, p = 0.087). DM was found to be a significant predictor of HPR in a multivariable analysis (odds ratio [OR], 1.76; 95% confidence interval [CI], 1.19 to 2.62; p = 0.004). In contrast, patients undergoing triple anti-platelet therapy (OR, 0.47; 95% CI, 0.31 to 0.70; p = 0.001) or who were smokers (OR, 0.63; 95% CI, 0.42 to 0.94; p = 0.022) were less likely to have HPR.

Figure 1

Post-treatment P2Y12 reaction units (PRU) values according to diabetic status and anti-platelet therapy. The difference between diabetes mellitus (DM) and non-DM patients was significant (p = 0.001). The lines inside the boxes denote the medians. The boxes mark the interval between the 25th and 75th percentiles.

Figure 2

Frequency of high platelet reactivity (HPR) according to diabetic status and anti-platelet therapy. The difference between diabetes mellitus (DM) and non-DM patients was significant (p = 0.002).

Table 2

Mean PRU and % inhibition values according to diabetic status and anti-platelet therapy

Table 3

Frequency of high platelet reactivity according to diabetic status and anti-platelet therapy

There was no significant difference in post-treatment PRU values (256.2 ± 114.2 vs. 234.6 ± 76.7, p = 0.299) or the frequency of HPR (55.6% vs. 42.4%, p = 0.455) based on the treatment modality, i.e., either insulin or oral hypoglycemic agents. In addition, there was no significant difference in post-treatment PRU values (241.3 ± 82.9 vs. 231.8 ± 81.9, p = 0.504) or the frequency of HPR (46.7% vs. 40.8%, p = 0.602) based on the status of diabetic control, which was based on a hemoglobin level of A1c 7.0.

DISCUSSION

The current study included a large number of consecutive patients recruited from real-world practice. Within this study population, a point-of-care assay could detect elevated post-treatment platelet reactivity and impaired responsiveness to clopidogrel in patients with type 2 DM compared to those without DM. The current study shows 1) higher post-treatment PRU values and 2) a higher frequency of HPR in patients with DM compared to patients without DM. Furthermore, higher post-treatment PRU values and a higher frequency of HPR were observed in patients with DM undergoing triple anti-platelet and dual anti-platelet therapy. However, the higher post-treatment PRU values observed in diabetic patients were significantly decreased with triple anti-platelet therapy as compared to dual anti-platelet therapy.

Several studies have reported that impaired platelet responsiveness to clopidogrel is more frequent in patients with type 2 DM [7,8,13]. Insulin normally inhibits platelet aggregation via inhibition of the P2Y12 pathway. However, patients with type 2 DM show reduced responsiveness to insulin, leading to up-regulation of the P2Y12 pathway and elevated platelet reactivity, which results in reduced responsiveness to anti-platelet therapy [6,8,14]. Reduced responsiveness to clopidogrel has been associated with adverse outcomes after PCI, including stent thrombosis [15-18]. Furthermore, the wide inter-individual variability in the inhibitory effects of clopidogrel is well-established [19,20]. Therefore, evaluation of individual clopidogrel responsiveness has become common in patients undergoing PCI, especially in patients with higher risks, such as those with DM.

Several methods have been used to evaluate clopidogrel responsiveness to identify patients at a higher risk of adverse events [21]. Light transmittance aggregometry following several agonist stimuli has been considered the gold standard method for platelet function analysis in previous studies; however, the routine use of this method in clinical practice is difficult because of the need for well-trained personnel and blood sample centrifugation [22]. Vasodilator-stimulated phosphoprotein phosphorylation as measured by flow cytometry also has limitations in clinical practice, although this method has a higher specificity as compared with that of aggregometry [22].

Recently, efforts have focused on formulating appropriate and cost-effective platelet function tests to measure platelet reactivity and clopidogrel hyporesponsiveness so that anti-platelet therapy can be individualized. A point-of-care assay specifically measures the inhibitory effects of clopidogrel on P2Y12 platelet receptor activation. Point-of-care assay results have been shown to be closely correlated with ADP-induced light transmittance aggregometry [23-25]. Several studies have shown that post-treatment PRU values ≥ 235 or 240, as measured by a point-of-care assay, are associated with an increased risk of post-PCI adverse events, including cardiac death, myocardial infarction, and stent thrombosis [11,12,26]. Our findings show a higher frequency of HPR in patients with DM as compared to those without DM. These results are consistent with a study reported by Price et al. [26], in which the frequency of high platelet reactivity (PRU ≥ 235) was significantly higher than lower platelet reactivity in patients with DM. Similar findings were also reported in a study by Marcucci et al. [12], where the frequency of residual platelet reactivity (PRU ≥ 240) was significantly higher in patients with DM.

The appropriate management of impaired clopidogrel responsiveness in drug-eluting stent treatment remains to be determined. A high clopidogrel maintenance dose can increase platelet inhibition in patients treated with PCI [27], including those with DM [28]. Another approach to consider might be the addition of a phosphodiesterase III inhibitor such as cilostazol to dual anti-platelet therapy. One study showed that the addition of cilostazol to dual anti-platelet therapy resulted in higher ADP-induced platelet inhibition as compared to dual anti-platelet therapy alone [9]. Another study showed that additional cilostazol reduced the rate of high post-treatment platelet reactivity and intensified platelet inhibition as compared to a high maintenance dose of clopidogrel (150 mg/day) [29]. Previous studies used light transmittance aggregometry to demonstrate higher platelet inhibition with triple anti-platelet therapy as compared to dual anti-platelet therapy in the general population [9,29]. In contrast, our findings showed that adjunctive cilostazol has additional anti-platelet effects in patients with type 2 DM as measured with a point-of-care assay.

There was no significant difference in post-treatment PRU values or the frequency of HRP depending on the type of treatment modality or the status of diabetic control (based on a hemoglobin level of A1c 7.0) in the patients with DM. Because a smaller number of patients were treated with insulin and a greater number of patients had relatively good diabetic control in the current study, further studies are warranted to examine patients treated with insulin as compared to those with uncontrolled DM.

The limitations of the current study include the following. First, the current study was based on an analysis of registry data; therefore, there were some discrepancies in the period of use of the anti-platelet agents from onset of anti-platelet therapy to the platelet function test among individual patients. However, a relatively large number of study subjects were assessed and there was no statistical difference in the period of use of anti-platelet agents. Second, because the current study was not a randomized trial, there may be a selection bias in the analysis of triple anti-platelet therapy effects in patients with DM. Third, the current study focused on the results of a point-of-care assay; therefore, the clinical effects, according differences in the degree of platelet inhibition, were not assessed in association with the results of the point-of-care assay. Additional prospective, randomized studies including clinical data are planned at our institution. Finally, the mean post-treatment PRU value in patients undergoing dual anti-platelet therapy was somewhat higher than that reported in two previously published studies [12,26]. One study identified a higher prevalence of cytochrome P450 2C19 genetic polymorphisms in an Oriental population as compared with westerners, which could be a possible explanation for this discrepancy [30].

In conclusion, the results of the current study show that a point-of-care assay can detect elevated platelet reactivity and impaired responsiveness to clopidogrel in type 2 DM patients after coronary stent implantation. The addition of cilostazol to dual anti-platelet therapy may decrease post-treatment PRU values and the frequency of HPR in patients with type 2 DM. Investigation of the clinical events associated with impaired responsiveness to clopidogrel in patients with DM is warranted.

Notes

No potential conflict of interest relevant to this article was reported.

References

1. Comparison of coronary bypass surgery with angioplasty in patients with multivessel disease: the Bypass Angioplasty Revascularization Investigation (BARI) Investigators. N Engl J Med 1996;335:217–225. 8657237.
2. Mak KH, Moliterno DJ, Granger CB, et al. Influence of diabetes mellitus on clinical outcome in the thrombolytic era of acute myocardial infarction. GUSTO-I Investigators. Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Coronary Arteries. J Am Coll Cardiol 1997;30:171–179. 9207639.
3. Malmberg K, Yusuf S, Gerstein HC, et al. Impact of diabetes on long-term prognosis in patients with unstable angina and non-Q-wave myocardial infarction: results of the OASIS (Organization to Assess Strategies for Ischemic Syndromes) Registry. Circulation 2000;102:1014–1019. 10961966.
4. Iakovou I, Schmidt T, Bonizzoni E, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005;293:2126–2130. 15870416.
5. Vinik AI, Erbas T, Park TS, Nolan R, Pittenger GL. Platelet dysfunction in type 2 diabetes. Diabetes Care 2001;24:1476–1485. 11473089.
6. Ferroni P, Basili S, Falco A, Davi G. Platelet activation in type 2 diabetes mellitus. J Thromb Haemost 2004;2:1282–1291. 15304032.
7. Colwell JA, Nesto RW. The platelet in diabetes: focus on prevention of ischemic events. Diabetes Care 2003;26:2181–2188. 12832332.
8. Angiolillo DJ, Fernandez-Ortiz A, Bernardo E, et al. Platelet function profiles in patients with type 2 diabetes and coronary artery disease on combined aspirin and clopidogrel treatment. Diabetes 2005;54:2430–2435. 16046311.
9. Lee BK, Lee SW, Park SW, et al. Effects of triple antiplatelet therapy (aspirin, clopidogrel, and cilostazol) on platelet aggregation and P-selectin expression in patients undergoing coronary artery stent implantation. Am J Cardiol 2007;100:610–614. 17697815.
10. Ahn JC, Song WH, Kwon JA, et al. Effects of cilostazol on platelet activation in coronary stenting patients who already treated with aspirin and clopidogrel. Korean J Intern Med 2004;19:230–236. 15683111.
11. Patti G, Nusca A, Mangiacapra F, Gatto L, D'Ambrosio A, Di Sciascio G. Point-of-care measurement of clopidogrel responsiveness predicts clinical outcome in patients undergoing percutaneous coronary intervention results of the ARMYDA-PRO (Antiplatelet therapy for Reduction of MYocardial Damage during Angioplasty-Platelet Reactivity Predicts Outcome) study. J Am Coll Cardiol 2008;52:1128–1133. 18804738.
12. Marcucci R, Gori AM, Paniccia R, et al. Cardiovascular death and nonfatal myocardial infarction in acute coronary syndrome patients receiving coronary stenting are predicted by residual platelet reactivity to ADP detected by a point-of-care assay: a 12-month follow-up. Circulation 2009;119:237–242. 19118249.
13. Angiolillo DJ, Bernardo E, Ramírez C, et al. Insulin therapy is associated with platelet dysfunction in patients with type 2 diabetes mellitus on dual oral antiplatelet treatment. J Am Coll Cardiol 2006;48:298–304. 16843179.
14. Ferreira IA, Mocking AI, Feijge MA, et al. Platelet inhibition by insulin is absent in type 2 diabetes mellitus. Arterioscler Thromb Vasc Biol 2006;26:417–422. 16339499.
15. Snoep JD, Hovens MM, Eikenboom JC, van der Bom JG, Jukema JW, Huisman MV. Clopidogrel nonresponsiveness in patients undergoing percutaneous coronary intervention with stenting: a systematic review and meta-analysis. Am Heart J 2007;154:221–231. 17643570.
16. Buonamici P, Marcucci R, Migliorini A, et al. Impact of platelet reactivity after clopidogrel administration on drug-eluting stent thrombosis. J Am Coll Cardiol 2007;49:2312–2317. 17572245.
17. Matetzky S, Shenkman B, Guetta V, et al. Clopidogrel resistance is associated with increased risk of recurrent atherothrombotic events in patients with acute myocardial infarction. Circulation 2004;109:3171–3175. 15184279.
18. Hochholzer W, Trenk D, Bestehorn HP, et al. Impact of the degree of peri-interventional platelet inhibition after loading with clopidogrel on early clinical outcome of elective coronary stent placement. J Am Coll Cardiol 2006;48:1742–1750. 17084243.
19. Gurbel PA, Bliden KP, Hiatt BL, O'Connor CM. Clopidogrel for coronary stenting: response variability, drug resistance, and the effect of pretreatment platelet reactivity. Circulation 2003;107:2908–2913. 12796140.
20. Price MJ, Coleman JL, Steinhubl SR, Wong GB, Cannon CP, Teirstein PS. Onset and offset of platelet inhibition after high-dose clopidogrel loading and standard daily therapy measured by a point-of-care assay in healthy volunteers. Am J Cardiol 2006;98:681–684. 16923461.
21. Gurbel PA, Becker RC, Mann KG, Steinhubl SR, Michelson AD. Platelet function monitoring in patients with coronary artery disease. J Am Coll Cardiol 2007;50:1822–1834. 17980247.
22. Michelson AD. Platelet function testing in cardiovascular diseases. Circulation 2004;110:e489–e493. 15533872.
23. van Werkum JW, van der Stelt CA, Seesing TH, Hackeng CM, ten Berg JM. A head-to-head comparison between the VerifyNow P2Y12 assay and light transmittance aggregometry for monitoring the individual platelet response to clopidogrel in patients undergoing elective percutaneous coronary intervention. J Thromb Haemost 2006;4:2516–2518. 16938130.
24. Malinin A, Pokov A, Swaim L, Kotob M, Serebruany V. Validation of a VerifyNow-P2Y12 cartridge for monitoring platelet inhibition with clopidogrel. Methods Find Exp Clin Pharmacol 2006;28:315–322. 16845449.
25. Paniccia R, Antonucci E, Gori AM, et al. Different methodologies for evaluating the effect of clopidogrel on platelet function in high-risk coronary artery disease patients. J Thromb Haemost 2007;5:1839–1847. 17723123.
26. Price MJ, Endemann S, Gollapudi RR, et al. Prognostic significance of post-clopidogrel platelet reactivity assessed by a point-of-care assay on thrombotic events after drug-eluting stent implantation. Eur Heart J 2008;29:992–1000. 18263931.
27. von Beckerath N, Kastrati A, Wieczorek A, et al. A double-blind, randomized study on platelet aggregation in patients treated with a daily dose of 150 or 75 mg of clopidogrel for 30 days. Eur Heart J 2007;28:1814–1819. 17272357.
28. Angiolillo DJ, Shoemaker SB, Desai B, et al. Randomized comparison of a high clopidogrel maintenance dose in patients with diabetes mellitus and coronary artery disease: results of the Optimizing Antiplatelet Therapy in Diabetes Mellitus (OPTIMUS) study. Circulation 2007;115:708–716. 17261652.
29. Jeong YH, Lee SW, Choi BR, et al. Randomized comparison of adjunctive cilostazol versus high maintenance dose clopidogrel in patients with high post-treatment platelet reactivity: results of the ACCEL-RESISTANCE (Adjunctive Cilostazol Versus High Maintenance Dose Clopidogrel in Patients With Clopidogrel Resistance) randomized study. J Am Coll Cardiol 2009;53:1101–1109. 19324253.
30. Desta Z, Zhao X, Shin JG, Flockhart DA. Clinical significance of the cytochrome P450 2C19 genetic polymorphism. Clin Pharmacokinet 2002;41:913–958. 12222994.

Article information Continued

Figure 1

Post-treatment P2Y12 reaction units (PRU) values according to diabetic status and anti-platelet therapy. The difference between diabetes mellitus (DM) and non-DM patients was significant (p = 0.001). The lines inside the boxes denote the medians. The boxes mark the interval between the 25th and 75th percentiles.

Figure 2

Frequency of high platelet reactivity (HPR) according to diabetic status and anti-platelet therapy. The difference between diabetes mellitus (DM) and non-DM patients was significant (p = 0.002).

Table 1

Baseline characteristics

Table 1

Values are presented as mean ± SD or number (%).

DM, diabetes mellitus; PCI, percutaneous coronary intervention; CABG, coronary artery bypass graft; ACE, angiotensin converting enzyme; ARB, angiotensin receptor blocker; CYP 3A4, cytochrome P450 3A4 isoenzyme.

aHypertension: blood pressure greater than 140/90 mmHg or medically treated.

bHypercholesterolemia: serum cholesterol greater than 200 mg/dL or medically treated.

cTriple anti-platelet agents: aspirin, clopidogrel, and cilostazol.

dDuration of anti-platelet therapy: from onset of therapy to the platelet function test.

Table 2

Mean PRU and % inhibition values according to diabetic status and anti-platelet therapy

Table 2

Numbers in parentheses denote the number of patients.

PRU, P2Y12 reaction unit; DM, diabetes mellitus.

aDual therapy: aspirin and clopidogrel.

bTriple therapy: aspirin, clopidogrel, and cilostazol.

cp value between dual therapy and triple therapy in DM or non-DM patients.

Table 3

Frequency of high platelet reactivity according to diabetic status and anti-platelet therapy

Table 3

Values are presented as number (%).

HPR, high platelet reactivity; DM, diabetes mellitus; NA, not available.

aDual therapy: aspirin and clopidogrel.

bTriple therapy: aspirin, clopidogrel, and cilostazol.

cp value between dual therapy and triple therapy in DM or non-DM patients.