| Home | E-Submission | Sitemap | Contact Us |  
Korean J Intern Med > Volume 34(1); 2019 > Article
Kim, Kim, Park, and Choe: Cardiac computed tomography reveals aortic valve perforation in a patient with severe aortic regurgitation
A 64-year-old man with moderate to severe aortic regurgitation without subjective symptoms who was followed for 7 months presented to the outpatient clinic with dyspnea. He had no history of fever or chills. C-reactive protein was elevated. Transthoracic echocardiography (TTE) revealed severe eccentric aortic regurgitation due to a prolapsed aortic valve (left coronary cusp and non-coronary cusp) and malcoaptation (Fig. 1A). These findings were worse than demonstrated on TTE 8 months prior (Fig. 1B). For the evaluation of coronary artery disease before elective aortic valve replacement, cardiac computed tomography (CT) was performed and demonstrated non-coronary cusp prolapse consistent with TTE as well as additional perforation (Fig. 2). Then, transesophageal echocardiography (TEE) confirmed the presence of a 2-mm-sized perforation in the non-coronary cusp (Fig. 1C). In the surgical field, there was a deformity in the non-coronary cusp and right coronary cusp. After diagnosis with culture-negative endocarditis, the patient was treated with 4 weeks of ampicillin-sulbactam and 2 weeks of gentamicin. The patient recovered and was discharged uneventfully. We received informed consent from the patient. In this case, aortic valve perforation, which did not appear on TTE, was demonstrated on a three-dimensional reconstruction of electrocardiography-gated cardiac CT. The perforation was confirmed on TEE. Anatomical information regarding the coronary artery and great vessels obtained via CT could be useful for surgical planning.

Conflict of interest

No potential conflict of interest relevant to this article was reported.

Figure 1.
(A) Two-dimensional color Doppler transthoracic echocardiography shows a prolapsed non-coronary cusp of the aortic valve (white arrow) with severe eccentric aortic regurgitation on the parasternal long axis view. (B) Two-dimensional color Doppler transthoracic echocardiography performed 8 months before reveals less severe aortic regurgitation flow without a difference in direction. (C) Transesophageal echocardiography demonstrates a 2-mm-sized perforation (white arrow) of the non-coronary cusp on the 0° view biplane two-dimensional image. Color Doppler imaging shows two regurgitation flows, eccentric jets through a perforation site and through a prolapse site (red and yellow arrows).
kjim-2018-109f1.jpg
Figure 2.
(A) Cardiac computed tomography demonstrates a prolapsed non-coronary cusp of the aortic valve (black arrow) during diastole on the cine image. (B) Aortic valve perforation of the non-coronary cusp is detected during systole in the cine image (black arrow). (C) Aortic valve perforation can be seen on the three-dimensional volume rendering and virtual endoscopic view (white and black arrows).
kjim-2018-109f2.jpg
TOOLS
PDF Links  PDF Links
PubReader  PubReader
ePub Link  ePub Link
Full text via DOI  Full text via DOI
Full text via PMC  Full text via PMC
Download Citation  Download Citation
CrossRef TDM  CrossRef TDM
  E-Mail
  Print
Share:      
METRICS
0
Crossref
0
Scopus
1,567
View
69
Download
Related article
Editorial Office
101-2501, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-2271-6792   Fax: +82-2-790-0993    E-mail: kaim@kams.or.kr
Copyright © 2019 The Korean Association of Internal Medicine. All rights reserved.
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
powerd by m2community